Project background
Sub-1G propagation suited the metal-heavy corridor environment. Inspection, maintenance and control room staff were placed on three groups, and the gateway connected to the control room network over Ethernet for a permanent dispatch position.
Metal structures and long pipe corridors attenuate radio signals, and mobile coverage inside the plant is inconsistent. Inspectors reading gauges in the corridor need to confirm values with the control room while they are still at the measurement point, not after walking back to an open area.
Deployment approach
The gateway was installed in the control room equipment rack and connected to the plant network over Ethernet, which gave the control room a permanent dispatch position instead of a handset passed between operators.
Eighteen terminals were assigned to three groups: inspection rounds, maintenance and control room. Inspection readings are confirmed within the inspection group, while maintenance coordination and control room instructions stay on their own groups.
Terminals carry replaceable batteries and charge over Type-C in the shift room. Inspection rounds were planned around two battery packs per terminal so a full shift and an overtime handover are both covered.
System specification
Published values from the KingNeed technical datasheet, paired with how they are applied in this deployment.
32
Terminal capacity
18 in use
4
Independent groups
3 in use
8
Full-duplex users
per group
Sub-1G
Private network
local deployment
- Voice mode
- Full-duplex voice, 8 users per group across 3 active groups
- Audio processing
- Microphone and speaker at the control room desk
- Headset / audio interface
- Handheld terminals in the corridor; control room uses the gateway audio ports
- Security
- PUF hardware authentication for terminals on the plant network
- Power
- Gateway on rack DC supply; two battery packs per terminal
Network configuration
- Terminals
- 18 handheld terminals
- Independent groups
- 3 (inspection / maintenance / control room)
- Gateway
- 1 cluster gateway in the control room rack
- Network
- Sub-1G private network, Ethernet link to the plant network
- Accessories
- Microphone and speaker at the control room desk, two battery packs per terminal
Deployment outcome
- Readings are confirmed with the control room while the inspector is still at the measurement point.
- Voice contact holds along pipe corridors where mobile coverage is inconsistent.
- Control room, inspection and maintenance traffic stay on separate groups.